Commercial Access Control Installation in Houston and Austin

Mayer Security Services installs commercial access control systems that decide who can open which door, at what time, and keep a record of every entry. We survey each opening, select lock hardware that satisfies the fire and building code, obtain the electronic lock permit your city or county requires, install and program the system, and test it with the fire alarm before handover. Work is performed across Houston, Austin and Texas under DPS Private Security License C28670101.

Platforms
Avigilon Alta and Unity, AXIS Camera Station, Hanwha OnCAFE, LTS
Credentials
Card, fob, PIN, phone, biometric
Permits
Electronic lock permit filed and inspected
License
Texas DPS C28670101
Scope

What does a commercial access control system include?

An access control system has four layers. At the door there is a credential reader, an electrified lock, a door position switch and a request to exit device. In the telecom room there is a door controller with a supervised power supply and battery, wired to the fire alarm panel. On the network there is the software that holds users, schedules and the audit trail, either on a server in the building or in the cloud. Around all of it is the procedure for issuing and removing credentials, which is where most systems succeed or fail.

A turnkey installation from Mayer Security Services covers every layer: the door by door survey, hardware schedule and drawings, the permit and inspection, cabling, mounting and termination, programming of access levels and schedules, enrollment of your first users, training for administrators and a closeout package with as-built drawings and the sequence of operation for each door.

Anatomy

The parts of an access controlled door

The parts of an access controlled door A credential reader on the secure side, an electrified lock, a door position switch and a request to exit sensor all wire back to a door controller in the telecom room. The controller has a supervised power supply with battery backup, a relay from the fire alarm panel that releases the lock, and a network connection to the access control software. AT THE OPENING TELECOM ROOM Electrified lock strike, mortise or maglock Door position switch held open, forced open Request to exit sensor unlocks on approach, egress side Credential reader card, fob, PIN or phone, OSDP wiring, mounted within ADA reach range Push to exit button breaks lock power directly, where the code requires one Free egress at all times: lever or panic hardware always opens the door from inside. composite access cableplenum rated where required Door controller UL 294 listed, decides offline tamper and inputs supervised Power supply Class 2, battery backup, fused lock outputs Fire alarmpanel relay On fire alarm or loss of power, locks in the egress path release as the adopted code requires. Accesssoftware schedules, audit trail, linked camera video
Reader, lock, door position switch and exit devices wire back to a controller in the telecom room. The controller keeps working if the network or the server is down, and the fire alarm relay releases locks in the egress path.
Lock hardware

Which electrified lock is right for each door?

The lock is chosen for the door, the frame, the fire rating and the direction of escape, not for convenience of installation.

Lock typeHow it worksTypical useWhat to know
Electric strikeReplaces the strike plate in the frame and releases the latchOffice, suite and storage doors with lever sets or panic barsThe door’s own hardware still gives free egress. Available fail secure, so the door stays locked from outside on power loss.
Electrified lever or mortise lockThe lock itself has a solenoid or motor, with power carried through the hingeNew doors, fire rated doors, stairwellsKeeps the latch engaged, which a fire rated opening requires. The cleanest result when the door is specified with it.
Electrified panic hardwareThe exit bar retracts its latch electricallyMain entrances, assembly spaces, pairs of doorsWorks with automatic door operators and gives dogging by schedule.
Electromagnetic lockA magnet on the frame holds a steel plate on the doorGlass storefront doors, gates, doors where no other lock fitsAlways fail safe. Requires the release devices the egress code specifies and is the lock type plan reviewers examine most closely.
Delayed egress lockHolds an exit door for 15 seconds after it is pushed while an alarm soundsRetail emergency exits, memory care, loss prevention doorsAllowed only in certain occupancies and buildings, and must release at once on fire alarm.
Power loss

Fail safe or fail secure: what happens when the power goes out?

Fail safe and fail secure describe what the secure side of a lock does when it loses power. A fail safe lock unlocks. A fail secure lock stays locked from the outside. In both cases a person inside can still leave, because the lever or panic bar opens the door mechanically.

The choice is made door by door. Electromagnetic locks are fail safe by nature, so doors that rely on them are open during a long outage unless the power supply has battery backup sized for it. Exterior doors and rooms holding valuable or sensitive property are normally fail secure so an outage does not unlock the building. Stairwell doors and some doors in the egress path are required by code to unlock on fire alarm. We record the decision for every door in the hardware schedule, and the plan reviewer checks it. The rules are set out on our permits and code compliance page.

Credentials

Cards, fobs, phones or fingerprints?

CredentialHow it worksStrengthsLimits
Proximity card or fob (125 kHz)Sends a fixed number to the readerInexpensive and widely installedUnencrypted and easily copied with a handheld cloner. We recommend against it for new systems.
Encrypted smart card or fob (13.56 MHz)Card and reader authenticate each other with encryptionResists cloning. The standard choice for new installationsCards must be matched to the reader technology.
Mobile credentialA phone app presents the credential over Bluetooth or NFCNothing to hand out or collect, issued and revoked remotelyDepends on staff carrying a charged phone. Usually deployed alongside cards.
PINA code entered on a keypadNo credential to carryCodes are shared and observed. Used as a second factor, rarely alone.
BiometricFingerprint or face match at the readerCannot be lent or lostTexas law requires notice and consent before a biometric identifier is captured, and the data must be protected and destroyed on schedule.

Readers are wired with OSDP, the Open Supervised Device Protocol, where the platform supports it. OSDP encrypts and supervises the wire between reader and controller, which the older Wiegand interface does not.

Process

How an access control project runs

  1. Door survey

    Every opening is examined: door and frame material, fire label, existing hardware, swing, power, cable path and how people leave through it in an emergency.

  2. Hardware schedule and drawings

    A lock type, release devices, fail safe or fail secure decision and code reference for each door, with a riser diagram and floor plans.

  3. Permit

    We file the electronic lock or access control permit with the city or county and answer the plan reviewer’s comments.

  4. Installation

    Controllers and power supplies are mounted in the telecom room, cable is pulled to each opening, and locks, readers and sensors are fitted to the door maker’s listing.

  5. Programming

    Access levels, schedules, holidays, alarms and administrator roles are built to your organization chart. Door events are linked to the nearest camera.

  6. Testing and handover

    Each door is tested for entry, exit, forced and held open alarms, loss of power and fire alarm release, then inspected. Administrators are trained on issuing and removing credentials.

Video

Why tie access control to the cameras?

An access log says a credential was used. Video says who used it. When door events are linked to camera views, an administrator can click a forced door alarm and see the ten seconds around it, confirm whether the person badging in is the cardholder, and spot one badge admitting four people. That link is what turns two separate systems into evidence.

Avigilon Unity and Alta, and AXIS Camera Station Pro, manage doors and cameras in one interface. Other combinations are linked through the video management software. Mayer Security Services installs both sides, so the door, the camera view and the alarm rule are designed together. See security camera installation and, for sites with staffed posts, officers plus systems.

FAQ

Frequently asked questions

Do I need a permit to install access control on a commercial door?

In most of the Houston and Austin area, yes. The City of Houston, the City of Austin and unincorporated Harris County each require plan review and inspection before electrified locks go on commercial doors. Mayer Security Services prepares the submittal, files the permit and attends the inspection.

What decides the cost of access control per door?

The door itself decides most of it. Lock type, whether the door is fire rated, glass or aluminum, how far it is from the telecom room, and whether it needs an automatic operator or new hardware move the figure more than the reader does. Software licensing and the number of credentials are the other inputs. We price door by door from the survey.

Will the doors still work if the network or internet goes down?

Yes. Each door controller stores its users and schedules locally and keeps making access decisions on its own. Events are held in the controller and uploaded when the connection returns. This is true of both cloud and on premises platforms.

Can people always get out of an access controlled door?

Yes. The building and fire codes require free egress, so the lever or panic bar opens the door from the inside without a credential. Electromagnetic locks add release devices and a fire alarm connection to guarantee it. Access control restricts entry, never exit.

Can you reuse our existing readers, cards and door hardware?

Often. We test existing locks, wiring and readers during the survey. Sound electric strikes and cabling are commonly kept. Older 125 kHz proximity readers can be replaced with multi technology readers that accept your current cards while you move to encrypted ones.

How do we remove access when an employee leaves?

An administrator disables the credential in the software and it stops working at every door, typically within seconds, with no locks to rekey. We set up administrator roles and a written offboarding step during training so removal happens the same day.

Plan your security system with a licensed Texas integrator

Tell us about the site. We survey it, design the system, pull the permits your city or county requires, install it to code and hand it over configured and documented.

Texas DPS Private Security License C28670101. Houston and Austin offices.

Call (281) 202-9862 Request Consult