Not sure which one?
Pick the site and the officers, and your request opens with both answered.
Open the service pickerDesign, permit, install
Cameras and access control surveyed, engineered, permitted and installed to code under Texas DPS License C28670101.
How it worksMayer Security Services installs commercial access control systems that decide who can open which door, at what time, and keep a record of every entry. We survey each opening, select lock hardware that satisfies the fire and building code, obtain the electronic lock permit your city or county requires, install and program the system, and test it with the fire alarm before handover. Work is performed across Houston, Austin and Texas under DPS Private Security License C28670101.
An access control system has four layers. At the door there is a credential reader, an electrified lock, a door position switch and a request to exit device. In the telecom room there is a door controller with a supervised power supply and battery, wired to the fire alarm panel. On the network there is the software that holds users, schedules and the audit trail, either on a server in the building or in the cloud. Around all of it is the procedure for issuing and removing credentials, which is where most systems succeed or fail.
A turnkey installation from Mayer Security Services covers every layer: the door by door survey, hardware schedule and drawings, the permit and inspection, cabling, mounting and termination, programming of access levels and schedules, enrollment of your first users, training for administrators and a closeout package with as-built drawings and the sequence of operation for each door.
The lock is chosen for the door, the frame, the fire rating and the direction of escape, not for convenience of installation.
| Lock type | How it works | Typical use | What to know |
|---|---|---|---|
| Electric strike | Replaces the strike plate in the frame and releases the latch | Office, suite and storage doors with lever sets or panic bars | The door’s own hardware still gives free egress. Available fail secure, so the door stays locked from outside on power loss. |
| Electrified lever or mortise lock | The lock itself has a solenoid or motor, with power carried through the hinge | New doors, fire rated doors, stairwells | Keeps the latch engaged, which a fire rated opening requires. The cleanest result when the door is specified with it. |
| Electrified panic hardware | The exit bar retracts its latch electrically | Main entrances, assembly spaces, pairs of doors | Works with automatic door operators and gives dogging by schedule. |
| Electromagnetic lock | A magnet on the frame holds a steel plate on the door | Glass storefront doors, gates, doors where no other lock fits | Always fail safe. Requires the release devices the egress code specifies and is the lock type plan reviewers examine most closely. |
| Delayed egress lock | Holds an exit door for 15 seconds after it is pushed while an alarm sounds | Retail emergency exits, memory care, loss prevention doors | Allowed only in certain occupancies and buildings, and must release at once on fire alarm. |
Fail safe and fail secure describe what the secure side of a lock does when it loses power. A fail safe lock unlocks. A fail secure lock stays locked from the outside. In both cases a person inside can still leave, because the lever or panic bar opens the door mechanically.
The choice is made door by door. Electromagnetic locks are fail safe by nature, so doors that rely on them are open during a long outage unless the power supply has battery backup sized for it. Exterior doors and rooms holding valuable or sensitive property are normally fail secure so an outage does not unlock the building. Stairwell doors and some doors in the egress path are required by code to unlock on fire alarm. We record the decision for every door in the hardware schedule, and the plan reviewer checks it. The rules are set out on our permits and code compliance page.
| Credential | How it works | Strengths | Limits |
|---|---|---|---|
| Proximity card or fob (125 kHz) | Sends a fixed number to the reader | Inexpensive and widely installed | Unencrypted and easily copied with a handheld cloner. We recommend against it for new systems. |
| Encrypted smart card or fob (13.56 MHz) | Card and reader authenticate each other with encryption | Resists cloning. The standard choice for new installations | Cards must be matched to the reader technology. |
| Mobile credential | A phone app presents the credential over Bluetooth or NFC | Nothing to hand out or collect, issued and revoked remotely | Depends on staff carrying a charged phone. Usually deployed alongside cards. |
| PIN | A code entered on a keypad | No credential to carry | Codes are shared and observed. Used as a second factor, rarely alone. |
| Biometric | Fingerprint or face match at the reader | Cannot be lent or lost | Texas law requires notice and consent before a biometric identifier is captured, and the data must be protected and destroyed on schedule. |
Readers are wired with OSDP, the Open Supervised Device Protocol, where the platform supports it. OSDP encrypts and supervises the wire between reader and controller, which the older Wiegand interface does not.
Cloud managed access control, formerly Openpath, with mobile credentials and remote management of many sites from one login.
Avigilon systemsOn premisesServer based access control, formerly Access Control Manager, for enterprises that keep the system inside their own network, unified with Unity Video.
Avigilon systemsOn premisesVideo and door control in one interface, using AXIS A1210, A1610 and A1810-B network door controllers powered over Ethernet.
Axis systemsCloud and valueHanwha Vision’s cloud access control with the NHP-P400 controller, and LTS Defendas controllers and readers for smaller sites.
Cloud access controlEvery opening is examined: door and frame material, fire label, existing hardware, swing, power, cable path and how people leave through it in an emergency.
A lock type, release devices, fail safe or fail secure decision and code reference for each door, with a riser diagram and floor plans.
We file the electronic lock or access control permit with the city or county and answer the plan reviewer’s comments.
Controllers and power supplies are mounted in the telecom room, cable is pulled to each opening, and locks, readers and sensors are fitted to the door maker’s listing.
Access levels, schedules, holidays, alarms and administrator roles are built to your organization chart. Door events are linked to the nearest camera.
Each door is tested for entry, exit, forced and held open alarms, loss of power and fire alarm release, then inspected. Administrators are trained on issuing and removing credentials.
An access log says a credential was used. Video says who used it. When door events are linked to camera views, an administrator can click a forced door alarm and see the ten seconds around it, confirm whether the person badging in is the cardholder, and spot one badge admitting four people. That link is what turns two separate systems into evidence.
Avigilon Unity and Alta, and AXIS Camera Station Pro, manage doors and cameras in one interface. Other combinations are linked through the video management software. Mayer Security Services installs both sides, so the door, the camera view and the alarm rule are designed together. See security camera installation and, for sites with staffed posts, officers plus systems.
In most of the Houston and Austin area, yes. The City of Houston, the City of Austin and unincorporated Harris County each require plan review and inspection before electrified locks go on commercial doors. Mayer Security Services prepares the submittal, files the permit and attends the inspection.
The door itself decides most of it. Lock type, whether the door is fire rated, glass or aluminum, how far it is from the telecom room, and whether it needs an automatic operator or new hardware move the figure more than the reader does. Software licensing and the number of credentials are the other inputs. We price door by door from the survey.
Yes. Each door controller stores its users and schedules locally and keeps making access decisions on its own. Events are held in the controller and uploaded when the connection returns. This is true of both cloud and on premises platforms.
Yes. The building and fire codes require free egress, so the lever or panic bar opens the door from the inside without a credential. Electromagnetic locks add release devices and a fire alarm connection to guarantee it. Access control restricts entry, never exit.
Often. We test existing locks, wiring and readers during the survey. Sound electric strikes and cabling are commonly kept. Older 125 kHz proximity readers can be replaced with multi technology readers that accept your current cards while you move to encrypted ones.
An administrator disables the credential in the software and it stops working at every door, typically within seconds, with no locks to rekey. We set up administrator roles and a written offboarding step during training so removal happens the same day.
Tell us about the site. We survey it, design the system, pull the permits your city or county requires, install it to code and hand it over configured and documented.