MAYERSECURITY SERVICES

Security System Design and Engineering for Commercial Facilities

Security system design is the engineering step that decides what each camera must see, how each door must behave, and what network, power and storage the system needs before any cable is pulled. Mayer Security Services designs video surveillance and access control systems for commercial sites across Houston, Austin and the rest of Texas, and delivers the drawings and schedules the installation and the permit both depend on.

Method
Site survey, written requirements, calculated layout
Image targets
IEC 62676-4 pixel density per view
Deliverables
Device layout, cable and port schedules, storage calculation
License
Texas DPS C28670101
Why design first

What does a security system design include?

A security system design is a written and drawn answer to four questions: what has to be seen or controlled, what image or door behavior proves it, what equipment delivers that, and what infrastructure keeps it running. A design from Mayer Security Services covers the camera and door layout, the lens and resolution for every view, the cable paths and telecom rooms, the switch and power budget, the recording storage, and the software configuration the owner will operate.

Most systems that disappoint were never designed. Cameras were counted, not calculated, so a face at the gate is forty pixels wide and no one can be identified. A recorder was bought by drive size, not by retention, so video is gone in nine days. A magnetic lock was added to an exit door without the release devices the fire code requires. Design work removes each of those failures while they are still lines on a drawing.

Because Mayer Security Services also staffs sites with licensed security officers, our designs start from how incidents actually unfold on a property: where people cut a fence, which dock door is propped at shift change, what an officer needs on screen to decide in seconds. That operating knowledge shapes the camera views and door rules before the engineering starts.

Process

How Mayer designs a camera and access control system

Every project follows the same six steps, scaled to the size of the site.

  1. Site survey

    We walk the property in daylight and after dark, measure mounting heights and distances, photograph every proposed device location, and note lighting, glare, vegetation, power and existing cable paths.

  2. Operational requirements

    For each view and each door we write down the purpose in one sentence: detect a person at the fence line, identify a driver at the gate, record every badge at the server room. These sentences set the engineering targets.

  3. Camera layout and lens selection

    Each view gets a pixel density target, then a sensor resolution, focal length and mounting position that meets it. Fields of view are drawn to scale on the floor plan so blind spots are visible before installation.

  4. Door hardware and egress review

    Each controlled opening is checked against the adopted building and fire code: lock type, release devices, fire rating of the door, and ADA reach range for the reader.

  5. Network, power and storage

    We size PoE switches, uplinks, battery backup and recording storage from the device list, with spare capacity stated in the design so future cameras and doors do not force a rebuild.

  6. Drawings and submittals

    The package includes device layouts, riser diagram, cable and port schedules, equipment data sheets and the documents the local authority asks for in a permit application.

Image quality

Pixel density targets used in camera layout

The international video surveillance standard IEC 62676-4 defines how much detail a camera must place on a target for an operator to do a given task. We assign one of these levels to every camera view and then calculate the lens and resolution that reach it at the real distance.

TaskPixels per meterPixels per footWhat the operator can do
Detect25about 8Tell that a person or vehicle is present
Observe62about 19See clothing, direction and behavior
Recognize125about 38Confirm a person already known to the viewer
Identify250about 76Establish the identity of an unknown person beyond reasonable doubt

Pixel density on target equals horizontal resolution divided by the width of the scene at the target distance. A 4 megapixel camera (2,688 pixels wide) covering a 40 foot wide gate puts about 67 pixels per foot on a driver. The same camera covering a 150 foot wide lot puts about 18.

Storage

How much video storage does a commercial system need?

Storage is calculated, not guessed. The inputs are the number of cameras, the bit rate of each stream, the hours recorded per day and the number of days the owner must keep video. A single camera recording continuously at 4 megabits per second writes about 43 gigabytes per day, or about 1.3 terabytes over 30 days. Thirty-two such cameras need about 41 terabytes of usable storage before any allowance for redundancy.

Three design choices move that number more than anything else:

  • Compression. H.265 with the manufacturer’s smart codec, such as Axis Zipstream, Hanwha WiseStream or Avigilon HDSM SmartCodec, lowers bit rate in static scenes without lowering detail on moving objects.
  • Recording mode. Recording on motion or on analytic events cuts storage sharply in quiet areas. Continuous recording stays in place wherever a missed event is unacceptable.
  • Retention. Thirty days is a common baseline. Insurers, corporate policy, contracts or local ordinance may require more, and some regulated sites keep 90 days or longer.

The design states the retention target, the calculation behind it and the RAID level of the recording array, so the owner can verify after installation that the oldest recorded day matches what was specified.

Power

Power over Ethernet classes used in the power budget

Most cameras, readers and door controllers are powered over the network cable. The switch must supply the right standard on each port and enough total wattage for every device at once.

StandardCommon namePower at the switch portPower at the deviceTypical devices
IEEE 802.3afPoE15.4 W12.95 WFixed dome and bullet cameras, card readers
IEEE 802.3atPoE+30 W25.5 WCameras with heaters or strong IR, small PTZ cameras, intercoms
IEEE 802.3bt Type 3PoE++60 W51 WMultisensor cameras, PTZ cameras, door controllers that power locks
IEEE 802.3bt Type 4PoE++90 W71.3 WHeavy PTZ cameras with heaters and illuminators

A copper Ethernet channel is limited to 100 meters (328 feet). Longer runs are designed with fiber, a PoE extender or a remote switch in a new enclosure.

Deliverables

What you receive at the end of design

Scaled device layouts

Floor and site plans with every camera, reader, lock, controller and telecom room located, and each camera’s field of view drawn to scale.

Device and cable schedules

One line per device: model, mounting, lens, pixel density target, cable type, cable length, switch and port.

Riser and network diagram

How head end, telecom rooms and field devices connect, including fiber uplinks, VLANs and the boundary with the business network.

Storage and power calculations

Retention math for the recorder and a PoE and battery backup budget for every switch.

Door hardware schedule

Lock type, release devices, fire rating and code reference for every controlled opening.

Permit submittal documents

The drawings and data sheets the city, county or fire marshal requires for the project. See permits and code compliance.

FAQ

Frequently asked questions

Do I need a design before getting a quote for security cameras?

For a small site a walk through and a device count is enough to price the work. For any site with more than a handful of cameras, exterior coverage, controlled doors or a permit requirement, a design comes first, because the quote is only as accurate as the device list and cable distances behind it.

How do you decide how many cameras a building needs?

We do not start from a camera count. We list what must be detected, observed, recognized or identified, assign a pixel density to each view, and then find the fewest camera positions that meet every target. The count is the result of that calculation.

What resolution do I need to read a face or a license plate?

Identifying an unknown face takes about 250 pixels per meter, roughly 76 pixels per foot, across the face at the capture point. License plates are captured with a dedicated camera set up to the plate width, shutter speed and angle limits that the camera manufacturer publishes. Megapixels alone do not answer the question, because the same camera gives very different detail at 20 feet and at 200 feet.

How many days of video should a business keep?

Thirty days is the most common baseline for commercial sites in Texas. Your insurer, a corporate policy, a customer contract or a local ordinance may set a longer period. We calculate storage for the retention you choose and state it in the design.

Can you design around cameras and cabling we already have?

Yes. The survey records existing cameras, cable, switches and recorders, tests what is worth keeping, and the design shows which parts are reused and which are replaced. Cameras that follow the ONVIF standard can usually be recorded by a new video management system.

Does Mayer Security Services install what it designs?

Yes. The same firm that surveys and designs the system pulls the required permits, installs, configures and tests it, and trains your staff, under Texas Department of Public Safety Private Security License C28670101.

Plan your security system with a licensed Texas integrator

Tell us about the site. We survey it, design the system, pull the permits your city or county requires, install it to code and hand it over configured and documented.

Texas DPS Private Security License C28670101. Houston and Austin offices.

Call (281) 202-9862 Request Consult