Not sure which one?
Pick the site and the officers, and your request opens with both answered.
Open the service pickerDesign, permit, install
Cameras and access control surveyed, engineered, permitted and installed to code under Texas DPS License C28670101.
How it worksA critical infrastructure security camera system has to detect a person on a long perimeter in darkness and bad weather, show an operator what caused the alert, and keep recording at sites with no staff, no utility power and no wired network. Mayer Security Services designs and installs these systems for energy and utility sites along the Texas Gulf Coast and in Central Texas, from offices in Houston and Austin.
A critical infrastructure security camera system has to detect intrusion along the whole perimeter in any light, let an operator verify the cause, control and record every gate and building entry, and keep working through power and network outages.
The sites differ, and so do the designs:
Mayer Security Services also provides officers for critical infrastructure protection, so each design starts from how these sites are patrolled.
On a long perimeter a thermal camera detects and a visible light camera identifies, so the two are designed as a pair. Levels follow IEC 62676-4.
| Area | Purpose of the view | IEC 62676-4 level | Typical camera |
|---|---|---|---|
| Long perimeter | A person or vehicle at the fence in darkness, haze or light fog | Detect (25 px/m) | Thermal camera with analytics |
| Alert follow up | What the thermal camera detected, and where it went | Observe (62 px/m), recognize on zoom | PTZ camera steered to the alert |
| Vehicle and contractor gates | Driver, plate, vehicle and load | Identify (250 px/m) on the driver | Fixed camera at cab height, license plate camera on the lane |
| Process units, tank farms and loading racks | People in areas that should be empty | Observe (62 px/m) | Camera outside the classified boundary, or a listed explosion protected camera inside it |
| Substation yard and control house | Entry to the yard and every opening of the control house door | Detect in the yard, identify at the door | Thermal or multisensor on the yard, dome at the door |
| Remote well, pump and valve sites | Anyone on the pad when no crew is scheduled | Detect (25 px/m) | Low power camera with on board analytics and recording |
They run on solar and battery power and send video back over fiber, a wireless bridge or a cellular link, with recording at the site so nothing is lost when the link drops.
Each gate, building and enclosure gets its own credential rule, and contractors receive time limited credentials tied to a work authorization instead of a shared code or key.
Each gate opens for an enrolled credential or plate, or when an operator who can see the driver on the intercom releases it. See gate access and license plate recognition.
Crews are enrolled before the job, with badges that work only at their assigned gate and hours and stop on the last day.
Entry by card and PIN, a camera on the door and a short access list that is reviewed on a schedule.
A reader on the gate replaces shared padlock keys, and readers are wired with OSDP so tampering raises an alarm.
NDAA Section 889 (FAR 52.204-25) bars federal agencies from buying, and from contracting with entities that use, video surveillance equipment from certain manufacturers named in the law. Operators that hold federal contracts are directly affected, and contract and funding requirements change over the life of a system, so Mayer Security Services specifies compliant equipment on every critical infrastructure project.
The camera network is built as its own segmented system, so a camera on a remote fence is not a way into the business network or the process control network.
Installation requires a Texas private security license under Occupations Code Chapter 1702. In unincorporated Harris County, an Access Control System permit from the Harris County Engineer covers electronic locking systems, and alarm permits come from the Sheriff’s Office there and in unincorporated Travis County. A new 120 volt circuit is work for a licensed electrical contractor. Mayer Security Services confirms the requirements with the authority for each project. See permits and code compliance.
An alert is useful only when a person verifies it and someone is sent. At a staffed facility that is the control room operator or the gate officer. At an unstaffed site it is whoever the operator assigns, under a written procedure.
Few events are worth an alert: a person or vehicle crossing the perimeter, anyone on a remote pad when no crew is scheduled, a gate or enclosure opened without a credential, and a camera that is covered or offline.
Mayer Security Services provides licensed armed and unarmed officers and mobile patrol who can be written into that procedure. Our solar powered mobile security surveillance units with remote monitoring cover a site during construction or an outage. How officers and installed systems share alerts and reports is set out on the security officers and systems page.
It depends on the sensor resolution and the lens, and each manufacturer publishes the figure per model. We lay out thermal cameras from the published analytics range, the fence geometry and the terrain, with overlap so the ground beneath each pole is covered by the next camera.
Yes. A solar array and battery bank are sized from the load, the winter sun hours at the location and the days of autonomy required. Low power cameras, on board recording and a cellular or wireless link keep the load small.
Operators with federal contracts do, and for everyone else it is the sensible default. Section 889 binds federal agencies and the entities that contract with them. We specify compliant equipment on every critical infrastructure project, which avoids replacing cameras when a contract or funding source later requires it.
Recording continues at the site. Each camera records on board or to a local recorder, and the video backfills to the central server when the link returns. The lost link raises its own alert.
By design. Cameras and recorders sit on dedicated switches or VLANs behind a firewall with no route to process control, and remote viewing goes through an encrypted, role based connection.
Yes. Each site records locally and reports to one video management system, so an operator in Houston can view and search sites on the Gulf Coast and in Central Texas. Bandwidth at each site decides whether live video is continuous or on demand.
Tell us about the site. We survey it, design the system, pull the permits your city or county requires, install it to code and hand it over configured and documented.