Not sure which one?
Pick the site and the officers, and your request opens with both answered.
Open the service pickerDesign, permit, install
Cameras and access control surveyed, engineered, permitted and installed to code under Texas DPS License C28670101.
How it worksNDAA compliant security camera installation means every camera and recorder on the project comes from a manufacturer and product line not barred by Section 889 of the National Defense Authorization Act, and the installer can prove it model by model. Mayer Security Services designs and installs video surveillance and access control for city, county and state facilities and for federal contractors, from offices in Houston and Austin.
NDAA compliant security camera installation means no camera, recorder or related component on the project comes from a company barred by Section 889 of the National Defense Authorization Act, and the installer documents that for every model.
In plain terms, Section 889, written into federal contracts by FAR 52.204-25, bars federal agencies from buying video surveillance equipment from Hikvision, Dahua and Hytera, and telecommunications equipment from Huawei and ZTE. It also bars agencies from contracting with entities that use that equipment, which is why federal contractors must check the cameras in their own buildings. Since November 2022 the Federal Communications Commission has issued no new equipment authorizations for covered equipment from those companies.
Projects paid for with federal funds generally carry the same rule, and many public buyers write it into their own specifications. Mayer Security Services, a veteran owned Texas firm, treats it as the baseline for all public sector work.
Mayer Security Services installs Avigilon, Axis Communications, Hanwha Vision and LTS. Three state that their products comply, and the fourth markets two compliant lines. The table gives each manufacturer’s stated position and what we specify for public work.
| Manufacturer | Stated position on NDAA Section 889 | What we specify for public work |
|---|---|---|
| Avigilon | Avigilon states its products are NDAA compliant. | Avigilon cameras, recorders and access control as the design requires |
| Axis Communications | Axis states its portfolio complies with NDAA Section 889. | Axis cameras, door controllers and intercoms as the design requires |
| Hanwha Vision | Hanwha Vision states all its products are NDAA compliant. | Wisenet cameras and Wisenet WAVE video management as the design requires |
| LTS | LTS states that all Pro-X cameras and recorders are made outside China and are NDAA compliant, and lists only Pro-X and Pro-VS in its NDAA compliant catalog. | Pro-X and Pro-VS models only. We do not specify other LTS lines for public work. |
TAA, the Trade Agreements Act, is a separate federal purchasing requirement and is model specific. Axis states that some of its models are TAA compliant. When a solicitation calls for TAA, we confirm it model by model.
Public buildings mix open lobbies with rooms very few people may enter, and the IEC 62676-4 level for each view follows that split.
| Area | Purpose of the view | IEC 62676-4 level | Typical camera |
|---|---|---|---|
| Public entrances and lobbies | The face of each person entering | Identify (250 px/m) | Dome with wide dynamic range facing the door |
| Service counters and payment windows | Interaction between staff and the public, and cash handling | Recognize (125 px/m) | Compact dome above each window |
| Courthouse corridors and meeting rooms | Movement between public and staff areas | Observe (62 px/m) | Dome or fisheye camera |
| Staff and secure doors | The person matched to the credential used | Identify (250 px/m) | Dome at each controlled door |
| Public works yards and fuel islands | Vehicles, equipment and fuel after hours | Detect across the yard, recognize at the gate | Multisensor on poles, license plate camera at the gate |
| Records, evidence and server rooms | Every entry and what was handled | Identify (250 px/m) | Dome inside the door |
Access control in a public building separates the public, staff and the few people allowed into secure rooms. See access control installation for the hardware.
Doors between the lobby and staff areas carry readers, and public doors follow a schedule and lock at closing.
Entry is limited to a short named list, can require a card and a PIN, and is logged with video.
Judges, staff, jurors and the public use different routes. Readers on the doors between those routes keep them apart, and each door has a camera tied to its events.
Yard gates open for a staff credential or a fleet vehicle’s plate, and after hours entries are reported.
Readers are mounted within the ADA reach range of 15 to 48 inches above the floor, and every electrified lock is reviewed against the adopted building and fire code.
The staff ID badge can double as the credential, a lost badge is disabled when it is reported, and readers are wired with OSDP, the encrypted and supervised protocol that replaces Wiegand.
Mayer Security Services replaces non compliant cameras in phases, reusing the cabling that passes testing, so the building is never left without coverage.
We list every camera, recorder and encoder by manufacturer and model and mark each against Section 889.
Existing cable, PoE switches and mounts are tested and reused where they pass.
A compliant model is chosen for each view to meet its pixel density target, and storage is recalculated.
Cameras are replaced area by area, and the old recorder is kept offline until its video passes the retention period.
Removed equipment is listed by serial number for the agency’s asset records.
The agency receives the model list with compliance statements, as-built drawings and administrator credentials described below.
A public buyer should ask for a model list with compliance statements, as-built drawings and administrator credentials at closeout, and should write them into the solicitation so every bidder prices them.
Installed systems give a public facility a continuous record and a short list of alerts, and security officers supply presence and judgment at the door. The alerts worth sending are few: a secure door forced or held open, a person in a closed area after hours, a vehicle in the public works yard at night and a camera offline.
Each alert goes to a named recipient, usually the lobby officer or facility manager by day and whoever the agency designates after hours.
Mayer Security Services provides licensed armed and unarmed officers and mobile patrol through its government services, under the same Texas license that covers installation. The security officers and systems page describes the arrangement.
Section 889 names video surveillance equipment from Hikvision, Dahua and Hytera, along with telecommunications equipment from Huawei and ZTE. Federal agencies may not buy it or contract with entities that use it. Since November 2022 the FCC has also issued no new equipment authorizations for covered equipment from those companies.
Not directly. Section 889 governs federal agencies and those that contract with them, and it reaches local government when a project uses federal funds or when the buyer writes the requirement into its specification. We specify compliant equipment for all public work so the question does not come up later.
No. NDAA Section 889 bars equipment from named companies, while TAA is a separate federal purchasing requirement that is model specific. When a solicitation requires TAA, we confirm it for each model on the list.
Usually, yes. We test each run and reuse those that pass, along with mounts and conduit. A recorder from a barred manufacturer is replaced as well and kept offline until its video passes the retention period.
Yes. The agency receives administrator credentials for every camera, recorder, switch, controller and software account at closeout. We recommend changing them after handover so only agency staff hold them.
Permits and inspections apply as the authority requires, and public ownership does not by itself remove them. In Houston electrified locks are permitted through the Houston Permitting Center, and in Austin electric locking systems are reviewed by the Austin Fire Department or Development Services. We confirm the requirement with the authority for each project.
Tell us about the site. We survey it, design the system, pull the permits your city or county requires, install it to code and hand it over configured and documented.