Not sure which one?
Pick the site and the officers, and your request opens with both answered.
Open the service pickerDesign, permit, install
Cameras and access control surveyed, engineered, permitted and installed to code under Texas DPS License C28670101.
How it worksOffice building access control and security cameras have to move tenants, employees and visitors through the lobby, elevators and suite doors with little delay, keep everyone else out after hours, and tie every door event to video. Mayer Security Services designs and installs these systems for single tenant and multi tenant office buildings in Houston, Austin and across Texas, to the egress code and permit rules of each city and county.
An office building security system has to sort people into layers. The public reaches the lobby during business hours, tenants and employees pass it to the elevators and their own floor, a smaller group enters each suite, and a handful reach the server or records room. Each layer is a door, turnstile or elevator with a reader, paired with a camera so a door event can be checked against video.
In a multi tenant building the work is split. The landlord’s base building system covers the perimeter, lobby, elevators, stairwells and garage, and each tenant controls its own suite. Mayer Security Services designs base building systems for owners and suite systems for tenants.
Six kinds of opening are controlled: perimeter doors, the lobby, elevators, the garage, suite entries and secure rooms.
Main entrances are open during business hours and credential only at night and on weekends. Service and loading dock doors report when held open.
A staffed desk or optical turnstiles separate the public lobby from the elevators. Visitors get a credential that expires the same day.
Readers in the cab or elevator lobby limit which floors a credential can reach after hours, through an interface installed with the elevator contractor.
Vehicles enter with a reader, tag or license plate. Doors from the garage into the building are controlled like any perimeter door.
Each tenant entry gets a reader and an electrified lock with free exit, as described under access control installation. Glass doors need hardware made for them.
A reader with a PIN as a second factor, forced and held open alerts, and a camera on the door provide the audit trail.
Cameras go wherever a door decision is made and along the routes between. Levels follow IEC 62676-4: detect at 25 pixels per meter, observe 62, recognize 125, identify 250.
| Area | Purpose | IEC 62676-4 level | Typical camera |
|---|---|---|---|
| Main entrance | Capture every face entering | Identify | Wide dynamic range dome facing the doors |
| Reception and visitor desk | Record each visitor at check in | Recognize | Compact dome |
| Service doors and loading dock | Record deliveries and after hours entries | Identify at the door, observe the dock | Bullet outside, dome inside |
| Elevator lobbies | Show who reached each floor | Recognize | Compact dome |
| Stairwell doors | Record entry to and exit from the stair | Recognize | Dome at the ground floor exit |
| Garage entry and exit lanes | Record each plate | Identify, plus plate capture | License plate camera per lane |
| Garage levels and vestibules | See people and vehicles moving through | Detect, observe at vestibules | Bullets along drive aisles, domes at vestibules |
| Suite entries and secure rooms | Match a face to each door event | Identify | Dome inside, facing the door |
An exit door can be secured against entry, but it must always let people out. A stairwell door opens from the floor into the stair with one motion and no card, key or code. Whether the stair side may be locked, so people in the stair cannot walk back onto a floor, is decided by the adopted building and fire code and the fire marshal. Where it is allowed, the doors stay latched to keep their fire rating and the locks release on the signal the code specifies.
Other electrically locked doors follow the same principle. Under the 2021 International Building Code that Houston enforces, a door released by a sensor must also release on loss of power, on fire alarm or sprinkler activation, and from a push to exit button mounted 40 to 48 inches high within 5 feet of the door. Austin enforces the 2024 edition.
Houston requires an electronic locks permit with plan review, inspection and a tag on each door. The Austin Fire Department reviews floor plans, a door schedule and a written sequence of operation. Mayer Security Services confirms the requirements with the authority for each building and prepares the submittal. See permits and code compliance.
Mayer Security Services installs four manufacturers. In an office building the choice usually follows how the owner or tenant wants to run access control: on a server in the building or as a cloud service.
Every door event is linked to video. When a credential is granted or denied, or a door is forced or held open, the access system marks the recording from the camera at that door, so the property manager or lobby officer sees who was there without searching footage. Few events deserve an alert: a perimeter or server room door forced, a door held open past its limit, repeated denied attempts at a secure room, and a disabled credential presented at any reader.
Visitors are registered in advance by their host, checked in at the desk and given a credential for one day and one floor. After hours, a video intercom at the main entrance rings the tenant’s phone or the security desk, and whoever answers sees the caller before releasing the door. Employees can carry a mobile credential in place of a card, issued and revoked remotely.
Access is removed from one screen at the time of the termination, with nothing to collect. That is one part of workplace violence prevention, and it works when the lobby officer and the system are run together, as the security officers and systems page explains.
Human resources or the office manager disables the person in the access software as the meeting begins. Cards, fobs and mobile credentials stop working at once, returned or not.
In a multi tenant building both the suite system and the base building system are updated, so the credential also fails at the lobby, elevators and garage.
If the disabled credential is presented at any reader, the system alerts the security desk and marks the video from that door.
Where Mayer Security Services officers staff the lobby, they receive the name and the tenant’s instructions, and the person is flagged in the visitor system.
The audit trail shows which doors the credential opened in recent weeks, which helps account for keys, equipment and records.
Yes, when the two systems are planned to share it. The base building and suite systems can read the same card or mobile credential while each keeps its own list of who is allowed. Landlord and tenant agree on the credential format before readers are ordered.
Only where the adopted building and fire code allows it, and never against exit from the floor into the stair. Where it is permitted, the locks release as the code specifies and the door stays latched. We confirm the requirement with the fire marshal for each building.
Through a video intercom at the main entrance. The visitor calls the tenant or the security desk, the person answering sees the caller, and the door is released for that entry only.
In one step that takes effect at every door at once. Disabling the person in the access software stops every card, fob and mobile credential they hold, and nothing has to be collected.
Yes. Readers in the cab or the elevator lobby tell the elevator controller which floors a credential may select. The interface is installed with the building’s elevator contractor.
In Houston it can. The city’s exterior camera ordinance applies to certain businesses, including bars, nightclubs and convenience stores, and sets rules for exterior coverage, resolution and at least 30 days of retention. An office building with one of those tenants should plan for it.
Tell us about the site. We survey it, design the system, pull the permits your city or county requires, install it to code and hand it over configured and documented.