Not sure which one?
Pick the site and the officers, and your request opens with both answered.
Open the service pickerDesign, permit, install
Cameras and access control surveyed, engineered, permitted and installed to code under Texas DPS License C28670101.
How it worksGate access control decides which vehicles may enter a site and records each one, using a long range tag, a license plate recognition camera, a keypad, an intercom call or a phone credential to signal the gate operator. Mayer Security Services installs and configures gate access control and license plate recognition for truck yards, plants, warehouses and gated commercial properties in Houston, Austin and across Texas.
Vehicle gate access control works in three layers: a gate and operator that open and close the lane, safety devices that keep the gate from striking or trapping anyone, and an access control system that decides when to send the open signal. The access controller treats the gate as a door. A credential is presented, the controller checks it against the schedule, a relay signals the operator, and the event is logged.
Under the Texas Private Security Act, equipment that controls access through a gate is regulated like equipment on a door, and so is a camera system that records. Mayer Security Services installs both under Texas DPS License C28670101 and adds the gate to the same access control system that runs the building doors.
A vehicle is admitted by a tag, its license plate, a code, a call or a phone. Most commercial gates combine two or three.
| Method | How it works | Suits | Limits |
|---|---|---|---|
| Long range reader and tag | A reader at the lane reads a windshield tag without the vehicle stopping | Fleet vehicles and employees who enter daily | Each vehicle needs a tag, which can be moved to another vehicle |
| License plate recognition | A dedicated camera reads the plate and checks it against an approved list | Sites that want every vehicle logged without issuing hardware | Dirty, damaged or covered plates are missed. A plate identifies a vehicle, not its driver |
| Keypad | The driver enters a code at a pedestal | Low traffic gates and vendors with time limited codes | Codes get shared, and every vehicle stops |
| Intercom call | The driver calls a person who sees them, speaks to them and opens the gate | Visitors, deliveries and anyone not in the system | Depends on someone answering |
| Phone credential | The driver’s phone presents a mobile credential to a reader at the lane | Staff who already use phone credentials on building doors | The driver must stop within reader range |
Exit lanes are opened by a vehicle detection loop in the pavement, or by a second reader where exits must be logged.
A license plate recognition camera reads reliably only when it is installed for that one job: one camera per lane, a shallow angle, a fast shutter, infrared light and enough pixels across the plate.
License plate recognition should not be expected to read every plate, to identify a driver, or to work from a camera installed for general surveillance. It reads most clean plates on a slow, well lit lane and records an image of each one.
Mayer Security Services sells, installs and configures license plate cameras from all four manufacturers, including the Avigilon L6Q, LTS Pro-X LPR models, and Axis and Hanwha Vision cameras that support license plate reading. On government, critical infrastructure and federally funded sites, the only LTS models we specify are Pro-X and Pro-VS, the lines LTS lists in its NDAA compliant catalog.
Two standards apply to automated vehicle gates in the United States: UL 325, which covers the gate operator and its entrapment protection, and ASTM F2200, which covers how the gate itself is built. Entrapment protection matters because a commercial gate is heavy moving machinery that can crush a person between the gate and a post or wall.
UL 325 calls for two independent means of entrapment protection wherever a person could be caught, such as the operator’s own obstruction sensing plus a photo eye or contact edge. ASTM F2200 requires guarded openings and rollers and a gate that cannot fall if it leaves its track. Both treat a vehicle gate as for vehicles only, so pedestrians get a separate walk gate.
An access system only asks the operator to open and is never wired to bypass a safety input. Before connecting to an existing operator, Mayer Security Services checks that its entrapment devices are present and working.
Fire department access is decided by the local fire marshal. Depending on the jurisdiction, that means a fire department key switch or lock box at the gate and a way to open it when power is lost. We confirm the requirement for each address. See permits and code compliance.
Power and network reach a gate through conduit in a trench, over fiber, or by a wireless bridge with power at the gate.
Separate conduits carry line voltage for the operator and low voltage or fiber for the access devices, with spare capacity for a later lane. A new 120 volt circuit is work for a licensed electrical contractor.
Most gates sit beyond the 100 meter (328 foot) limit of copper Ethernet. Fiber to a small hardened PoE switch at the gate carries the cameras, reader and intercom and is immune to lightning induced surges. See low voltage cabling.
Where trenching across pavement or rail is not practical, a point to point radio link with clear line of sight carries the network. Power must still be present at the gate.
Gate equipment stands in the open on metal posts. Every copper cable leaving the enclosure gets a grounded surge protector.
A gate should be paired with an officer when the decision at the lane takes judgment: matching a driver to a load, checking paperwork or a trailer seal, turning a vehicle away, or acting when one vehicle follows another through. Readers and cameras admit known vehicles and record everything. An officer handles the exceptions.
That split fits truck yards and plants. Regular tractors and employees pass on a tag or plate without stopping, and the officer’s time goes to visitors and unscheduled loads, with a plate image and a time for every vehicle in the log.
Mayer Security Services provides licensed armed and unarmed officers and installs the gate systems under one Texas license, from offices in Houston and Austin. See logistics and truck yard security, commercial, industrial and warehouse security, and how security officers and systems work together.
Accuracy depends on the installation more than on the camera. A dedicated plate camera at a shallow angle with infrared light on a slow lane reads most clean plates, and no system reads every plate.
Not reliably. A general camera may show a plate in daylight. At night, headlights and automatic exposure wash the plate out.
Yes. The plate is matched against an approved list, and the access controller signals the operator and logs the plate, time and image. On higher security lanes we pair the plate with a tag or credential.
UL 325 is the safety standard for gate operators, including the entrapment protection that stops or reverses a gate when something is in its path. ASTM F2200 is the standard for how an automated vehicle gate is constructed.
By the method the local fire marshal requires for that address, commonly a fire department key switch or lock box at the gate. We confirm it with the fire marshal before the design is finished.
Not always. Fiber in conduit is the more dependable path. Where trenching is impractical, a point to point wireless bridge carries the network if there is line of sight and power at the gate.
Tell us about the site. We survey it, design the system, pull the permits your city or county requires, install it to code and hand it over configured and documented.